BodyRig

Block Catalogue / Devices

DLR BodyRig inertial motion capture. Takes IMU quaternions from an RN41 Bluetooth serial port (clock-driven) or from an upstream block, runs forward kinematics over a calibrated segment chain, and publishes per-segment orientation and position.

Input and output

Property Value
Type bodyrig
Inputs exactly 1 — the sender's type picks the mode: a ClockBlock → Serial, anything else → Upstream
Consumes Upstream: Vector<double>, 4 doubles per sensor as [w, x, y, z]. Serial: nothing from the pipeline (the tick is only a pump; 22-byte frames arrive at 115200 8N1)
Publishes Vector<double> of length numChannels × 7, per segment [W, X, Y, Z, posX, posY, posZ]

Parameters

# Name Type Default Meaning
0 portName string "" Serial port, e.g. COM5
1 numChannels int 10 Chain segments / IMU slots, clamped ≥1
2 calibrationDirectory string null Directory scanned for profiles; empty/whitespace → null, skipping the scan
3 profileFileName string "" Bare file name, matched case-insensitively inside [2]

Read via ToString(), not the JsonModel.GetX helpers — a non-numeric channel count silently leaves 10, and an unmatched profile name silently leaves the first file in the directory selected.

Requirements and use

Connect the serial device or supply quaternion vectors, then select a calibration profile matching the sensor layout. Confirm sensor order and segment geometry before interpreting positions. The Unity side channel uses localhost port 3339.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.