Fire-and-forget UDP command sender for ESP-based IMU nodes. Sends ASCII strings like ROT1on ({ROT|ACC|GYR|MAG|ALL}{deviceNo}{on|off}) to start/stop streams. Control plane only — it carries no pipeline data.

Input and output

Property Value
Type commandsender
Inputs 0; see usage below
Consumes nothing; OnReceive is empty
Publishes nothing; output is exclusively the UDP datagram

Parameters

# Name Type Default Meaning
0 hostIP string "192.168.1.255" Target address; .255 is a broadcast address by design (EnableBroadcast is set unconditionally)
1 port int 10015 UDP port; a non-numeric value throws ArgumentException

Constructor defaults (192.168.1.1 / 5000) differ from these ConfigureInput defaults.

Requirements and use

Set the destination host/port to your ESP nodes and send the appropriate start/stop command from the card. This block controls another source; it does not acquire IMU samples itself.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.