Depth Filter
Block Catalogue / Signal Processing
The same FIR/IIR designs as Filter, but applied along each row (the depth axis) with the state reset before every row, so frames are independent. Built for A-mode ultrasound lines and similar spatial signals.
Input and output
| Property | Value |
|---|---|
| Type | depthfilter |
| Inputs | exactly 1 |
| Consumes | Vector<double> (one depth line) or Matrix<double> [channels × depth samples] |
| Publishes | Vector<double> or Matrix<double> of identical shape; each row filtered independently. Also feeds a HeatMapMonitor and a SnapshotMonitor |
Parameters
| # | Name | Type | Default | Meaning |
|---|---|---|---|---|
| 0 | FilterType | string | Lowpass |
Lowpass | Highpass | Bandpass | Bandstop |
| 1 | Implementation | string | IIR |
IIR | FIR |
| 2 | CutoffLow | double | 50 | Lower cutoff (Hz, against DepthSampleRate) |
| 3 | CutoffHigh | double | 150 | Upper cutoff; used only for Bandpass/Bandstop, always read |
| 4 | Order | int | 4 | IIR order |
| 5 | FirTaps | int | 64 | FIR tap count |
| 6 | DepthSampleRate | double | 1000 | The only thing that sets the design rate |
All optional, positional, cumulative.
Requirements and use
Filters along each row with independent frame processing. Use it for a depth/spatial axis, not as a substitute for a time-domain filter that carries state between samples.
For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.
Implementation
API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.