Depth Filter

Block Catalogue / Signal Processing

The same FIR/IIR designs as Filter, but applied along each row (the depth axis) with the state reset before every row, so frames are independent. Built for A-mode ultrasound lines and similar spatial signals.

Input and output

Property Value
Type depthfilter
Inputs exactly 1
Consumes Vector<double> (one depth line) or Matrix<double> [channels × depth samples]
Publishes Vector<double> or Matrix<double> of identical shape; each row filtered independently. Also feeds a HeatMapMonitor and a SnapshotMonitor

Parameters

# Name Type Default Meaning
0 FilterType string Lowpass Lowpass | Highpass | Bandpass | Bandstop
1 Implementation string IIR IIR | FIR
2 CutoffLow double 50 Lower cutoff (Hz, against DepthSampleRate)
3 CutoffHigh double 150 Upper cutoff; used only for Bandpass/Bandstop, always read
4 Order int 4 IIR order
5 FirTaps int 64 FIR tap count
6 DepthSampleRate double 1000 The only thing that sets the design rate

All optional, positional, cumulative.

Requirements and use

Filters along each row with independent frame processing. Use it for a depth/spatial axis, not as a substitute for a time-domain filter that carries state between samples.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.