Muovi Single Probe
Block Catalogue / Devices
The same decode as Muovi, but for one probe connecting directly over Wi-Fi with no SyncStation: this block is the TCP server, binding 0.0.0.0:54321 and waiting for the probe to dial in.
Input and output
| Property | Value |
|---|---|
| Type | muovisingleprobe |
| Inputs | 0; see usage below |
| Consumes | a tick in vector mode (payload ignored); otherwise nothing — the reader thread pulls 76-byte samples (38 int16 columns) off the accepted socket |
| Publishes | Matrix<double> [samplesPerBatch × OutputChannels] or Vector<double> [OutputChannels] per tick. OutputChannels = 32 + (imu ? 4 : 0) |
Uses the same MuoviConstants.ConversionFactor table: electrode units are 1/32768 normalised in the default emg mode, mV/bit only in emg_lowgain, µV/bit in eeg. IMU raw int16.
Parameters
keyword-only bag, no positions.
| # | Name | Type | Default | Meaning |
|---|---|---|---|---|
| any | signal mode | string | emg |
eeg, emg_lowgain/lowgain, emg |
| any | imu |
string | off | Adds 4 quaternion channels |
| any | output mode | string | auto | matrix/matrixmode/batch or vector/vectormode/single |
Requirements and use
This block listens for the probe to connect, rather than dialing a SyncStation. Configure the Wi-Fi probe to reach the host and ensure that its receive port is free.
For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.
Implementation
API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.