Resampler

Block Catalogue / Signal Processing

Sample-and-hold rate converter. Selects or repeats values on a nominal sample-time grid. Packet sizes and callback speed do not determine which values it selects. Its output DesiredRate and SignalRate both equal TargetRate.

Input and output

Property Value
Type resampler
Inputs exactly 1
Consumes Vector<double>; Matrix<double> [timesteps × channels], rows fed through the timing logic individually; or the legacy ValueTuple<string, object>, unwrapped and re-dispatched
Publishes always Vector<double> — never a matrix, so matrix input becomes a stream of vectors (a type change driven by the input, not by a parameter)

Parameters

not positional. The whole list is scanned and the first usable entry wins: a targetRate:<n> / rate:<n> tagged string, or a bare positive number (InvariantCulture). Fallback chain: parsed value → DesiredRate → 100.0.

# Name Type Default Meaning
any TargetRate double 100.0 Publish rate in Hz. Zero or negative candidates are skipped, not rejected

Requirements and use

Input vectors use the source publication rate; contiguous matrix rows use its sample rate. If the source has no rate, the constructor/configuration DesiredRate is the input-rate fallback; if that is also absent, the target rate is assumed. Give the source correct metadata before interpreting the output as a resampled signal.

At 2 input samples/s and 4 output samples/s, inputs [10, 20, 30] at times [0, 0.5, 1] produce [10, 10, 20, 20, 30] at nominal times [0, 0.25, 0.5, 0.75, 1]. The held value at 0.25 arrives together with the input at 0.5. The block has no independent timer and cannot continue publishing after input stops.

Apply an appropriate low-pass filter before downsampling. This block does not perform anti-alias filtering, interpolate between values, detect missing packets, or synchronize device timestamps. Every matrix row is treated as new input; overlapping windows would replay old samples. The Scope uses the target cadence, while CSV timestamps still mark actual publication time.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Example

For the distinction between sample rate and publication rate, read Data and time. A resampler changes the sample stream by holding or selecting values; changing a plot's refresh rate does not. Do not use it as a timestamp synchronizer between devices.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.

Search documentation