SiFi
Block Catalogue / Devices
Source for SiFi Labs BLE biosignal wearables (BioArmband / BioPoint), driven by an external sifibridge child process whose JSON stdout is parsed into EMG/IMU/ECG/EDA/PPG streams.
Input and output
| Property | Value |
|---|---|
| Type | sifi |
| Inputs | 0; see usage below |
| Consumes | nothing from the graph; newline-delimited JSON from the sifibridge subprocess's stdout |
| Publishes | heterogeneous, three runtime types on one port: Matrix<double> [samples × channels] for armband EMG, Vector<double> for single-channel EMG, and ValueTuple<string, Vector<double>> tagged "imu", "ppg", "ecg", "eda" |
Parameters
| # | Name | Type | Default | Meaning |
|---|---|---|---|---|
| 0 | macAddress | string | required | Address of the user's paired device |
| 1 | bridgePath | string | "sifibridge" |
Executable, resolved on PATH |
| 2 | mainsNotch | enum | on50 |
off / on50 / on60; unparsable falls back to On50 |
| 3 | bandpassLow | double | 20 | Hz |
| 4 | bandpassHigh | double | 450 | Hz |
Requirements and use
Requires the SiFi bridge and a paired device. Confirm the requested signal channels and connection state on the card before starting acquisition.
For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.
Implementation
API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.