Slope Sign Changes

Block Catalogue / Flow Control

Counts slope sign reversals per channel per window — a standard EMG time-domain feature.

Input and output

Property Value
Type slopesignchanges, mosaic.models.flowcontrol.slopesignchanges, imblocks.blocks.flowcontrol.slopesignchanges
Inputs exactly 1
Consumes Matrix<double> only [samples × channels]; anything else → Stumbling
Publishes Vector<double>, one count (as a double) per column

Parameters

positional.

# Name Type Default Meaning
0 Threshold double 0.0 Minimum slope magnitude; both adjacent slopes must clear it. 0 counts every sign change.

Requirements and use

Use windowed data and choose the threshold for the units/noise level of the signal. The output is a per-channel feature, not a time-series reconstruction.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.