Zero Crossings
Block Catalogue / Flow Control
Counts sign changes through zero per channel per window — a cheap proxy for dominant frequency content.
Input and output
| Property | Value |
|---|---|
| Type | zerocrossings, mosaic.models.flowcontrol.zerocrossings, imblocks.blocks.flowcontrol.zerocrossings |
| Inputs | exactly 1 |
| Consumes | Matrix<double> only [samples × channels]; anything else → Stumbling |
| Publishes | Vector<double>, one count (as a double) per column |
Parameters
positional.
| # | Name | Type | Default | Meaning |
|---|---|---|---|---|
| 0 | Threshold | double | 0.0 | Minimum |current − next| on the crossing pair. Read through the tolerant JsonModel.GetDouble: a wrong value kind silently yields 0.0, and a numeric string like "0.01" parses fine. |
Requirements and use
Use windowed data. Noise and signal offset affect sign changes; condition the signal and keep the same window settings between training and prediction.
For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.
Implementation
API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.