Mock Ultrasound

Block Catalogue / Streaming

Synthetic ultrasound frame source for exercising the classifier/trigger-buffer pipeline with no hardware, emitting deterministic class-conditional grayscale patterns plus Gaussian noise.

Input and output

Property Value
Type mockultrasound
Inputs exactly 1 (normally the Clock)
Consumes dispatch by message type: Vector<double> → cached as activation weights, no frame emitted; anything else (e.g. the clock's double) → emit one frame
Publishes Matrix<double> of FrameHeight × FrameWidth

Parameters

# Name Type Default Meaning
0 NumClasses int 5 Number of class templates (clamped ≥1)
1 FrameHeight int 224 Rows (≥1)
2 FrameWidth int 224 Columns (≥1)
3 NoiseLevel double 0.05 Std-dev of additive Gaussian noise; negatives clamped to 0
4 WeightedMode string/bool (off) weighted, weighted_mode, blend, true, 1, or JSON true enable blending; surrounding whitespace is trimmed, any other value means label mode

Requirements and use

Use a compatible trigger/class input to generate the class-conditioned patterns expected by the training workflow. This provides synthetic images for development without ultrasound hardware.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.

Search documentation

Start typing to search the documentation.