Muovi
Block Catalogue / Devices
Streams HD-sEMG / EEG (optionally plus IMU quaternions) from up to 16 OT Bioelettronica Muovi probes attached to a SyncStation, over an outbound TCP connection to 192.168.76.1:54320.
Input and output
| Property | Value |
|---|---|
| Type | muovi |
| Inputs | 0; see usage below |
| Consumes | vector mode: a tick from an upstream ClockBlock (payload ignored). Matrix mode: nothing — the Muovi-Reader thread pulls int16 LE bursts (38 raw columns per probe + 6 accessory columns, 18 samples per burst) |
| Publishes | Matrix<double> of [samplesPerBatch × OutputChannels] (matrix mode) or Vector<double> of [OutputChannels] per tick (vector mode). OutputChannels = probes × (32 + (imu ? 4 : 0)) |
Electrode scaling is mode-dependent: default emg uses 1/32768 (normalised full-scale, dimensionless), emg_lowgain 0.000572 mV/bit, eeg 0.286 µV/bit. IMU columns are raw int16, unscaled.
Parameters
not positional; an unordered bag scanned by value, read via ToString().
| # | Name | Type | Default | Meaning |
|---|---|---|---|---|
| any | probe index | int | probe 0 | Zero-based probe slot, appended to ProbeIndices; if no integer appears, probe 0 is added |
| any | signal mode | string | emg |
emg, emg_lowgain/lowgain, eeg |
| any | imu |
string | off | Adds 4 quaternion channels per probe |
| any | output mode | string | auto | matrix/matrixmode/batch forces Matrix; vector/vectormode/single forces Vector |
Unrecognised strings are silently ignored. The real knobs are top-level DesiredRate (default 100) and Path.
Requirements and use
Connect through the SyncStation and configure the probes/channels. Confirm whether downstream blocks expect vectors or batched matrices; acquisition rate and publish rate need not be equal.
For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.
Implementation
API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.