Sin Generator
Block Catalogue / Streaming
Synthetic multi-channel sine source: on each clock tick it evaluates A·sin(2πft + φ₀ + i·Δφ) per channel, using a jitter-free internal sample counter rather than the incoming timestamp.
Input and output
| Property | Value |
|---|---|
| Type | singenerator, mosaic.models.singenerator |
| Inputs | exactly 1, and whitelisted to ClockBlock — nothing else may feed it |
| Consumes | the clock's double tick; the value is ignored, it only triggers evaluation |
| Publishes | Vector<double> with one scan; Matrix<double> with multiple scans (rows = scans, columns = channels) |
Parameters
| # | Name | Type | Default | Meaning |
|---|---|---|---|---|
| 0 | Components | int | 1 | Channel count (forced ≥1) |
| 1 | Amplitude | double | 1.0 | Peak amplitude |
| 2 | Frequency | double | 0.2 | Sine frequency in Hz; time base uses the true sample rate |
| 3 | Phase | double | 0.0 | Initial phase, radians |
| 4 | PhaseStep | double | 10.0 | Inter-channel phase offset, radians |
| 5 | ScansPerPacket | int | 1 | Samples per tick; values greater than 1 produce matrices |
Requirements and use
Start its upstream Clock. ScansPerPacket = 1 publishes a vector; larger values publish matrices with rows = scans and columns = components. The true sample rate is tick rate × scans per packet. Five-parameter configurations remain valid and default to one scan.
For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.
Example
Download a complete pipeline and follow Your First Pipeline. Start the Clock to generate data. The sine wave has amplitude 1 and frequency 1 Hz. Its square is nonnegative, and its doubled branch has amplitude 2.
Worked example
Compare the source in Signal Processing Walkthrough with the batched source: 256 one-row publications/s and 64 four-row packets/s both represent 256 samples/s.
Implementation
API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.