Sin Generator

Block Catalogue / Streaming

Synthetic multi-channel sine source: on each clock tick it evaluates A·sin(2πft + φ₀ + i·Δφ) per channel, using a jitter-free internal sample counter rather than the incoming timestamp.

Input and output

Property Value
Type singenerator, mosaic.models.singenerator
Inputs exactly 1, and whitelisted to ClockBlock — nothing else may feed it
Consumes the clock's double tick; the value is ignored, it only triggers evaluation
Publishes Vector<double> with one scan; Matrix<double> with multiple scans (rows = scans, columns = channels)

Parameters

# Name Type Default Meaning
0 Components int 1 Channel count (forced ≥1)
1 Amplitude double 1.0 Peak amplitude
2 Frequency double 0.2 Sine frequency in Hz; time base uses the true sample rate
3 Phase double 0.0 Initial phase, radians
4 PhaseStep double 10.0 Inter-channel phase offset, radians
5 ScansPerPacket int 1 Samples per tick; values greater than 1 produce matrices

Requirements and use

Start its upstream Clock. ScansPerPacket = 1 publishes a vector; larger values publish matrices with rows = scans and columns = components. The true sample rate is tick rate × scans per packet. Five-parameter configurations remain valid and default to one scan.

For parameter positions and connection rules, see Pipeline Configuration. For capturing output, see Recording.

Example

Download a complete pipeline and follow Your First Pipeline. Start the Clock to generate data. The sine wave has amplitude 1 and frequency 1 Hz. Its square is nonnegative, and its doubled branch has amplitude 2.

Worked example

Compare the source in Signal Processing Walkthrough with the batched source: 256 one-row publications/s and 64 four-row packets/s both represent 256 samples/s.

Implementation

API reference. Model defaults above describe configuration loading; palette hints may expose a subset or select different defaults.

Search documentation