Troubleshooting

Start with the smallest pipeline that reproduces the problem. The first example separates workbench issues from hardware setup.

No signal or a flat plot

  1. Check that the source is running. Press Play on a Clock; connect and start a device.
  2. Check connections and the load report. An unavailable block may leave the rest visible but disconnected.
  3. Enable the plot and select a channel. A hidden plot does not stop processing.
  4. Check signal frequency and sampling rate. A 0.2 Hz sine wave takes five seconds per cycle.
  5. Match the source's output shape to the consumer's accepted input.

Use Show log in the workbench for application messages. Subscriber failures are reported in the block's error state and written to the log; developers can attach a debugger when the logged exception does not explain a processing failure.

A block is missing or cannot load

Check Type against the Block Catalogue. The block may be excluded by the platform or build options. Preserve the original file before saving a partially loaded graph, then inspect its reported block name and error.

For hardware, check vendor libraries, ports, Bluetooth permissions and the connection sequence. Running MOSAIC on a platform does not imply every vendor's hardware is available there.

Recording is empty or missing

Check the folder, Record switch and source. Recording captures published output, not incoming data. Explicit recording paths override the shared destination. Allow the writer to flush or switch recording off to close the file. See Recording.

Unexpected data or plots

Before diagnosing an installation, use these checks for a running pipeline.

Wrong time scale or repeated-looking traces

Check the card's actual feed and the meaning of each row. Sliding Window's own scope shows its input; a feature scope shows one result per window. Compare with Signal Processing Walkthrough: 256 source samples/s, four MAV values/s. Display throttling and large-batch reduction can omit rows; batched-source window metadata has a known limitation. Reading the plots explains both.

No spectrum or a peak at the wrong frequency

Use a power-of-two window row count. Check the true sample rate and FFT scaling. With the example's 256-row window at 256 samples/s, expect 1 Hz bins and a peak at 8 Hz. Do not substitute the four-spectra/s publication rate for the acquisition sample rate.

Features start low or predictions stay constant

Allow startup padding and the filter to settle. After an amplitude change, wait until the window contains the new signal. Check the feature itself before the model. In the learning example, amplitude 1 gives MAV near 0.63 and amplitude 3 gives near 1.90. Capture both classes and keep evaluation capture stopped.

CSV columns or timestamps look wrong

For matrices, column two is a row index; all rows in one matrix share a publication timestamp. They are not simultaneous acquisitions. Use the CSV reader with the expected channel count and rows per matrix. Record upstream of windows if you need samples without repeated history.

Plot updates lag behind processing

Hide unnecessary plots and compare a short recording with the expected output shape/count. A responsive source does not prove that a downstream processing queue or disk writer is keeping up. Plot refresh, processing delivery and CSV queues have different policies; reducing display work does not remove a slow operation in the processing chain.

Build or launch errors

Symptom What to check
No compatible SDK Run dotnet --version from the solution directory; inspect global.json.
Multiple target frameworks Include the appropriate -f argument from Getting Started.
Missing Delsys package Delsys is disabled by default. Configure an authorised private vendor package source before using -p:EnableDelsys=true.
Missing platform workload Install the workload and platform SDK for the selected application project.
iOS signing error Select your own team, identity and device on the build Mac.
Bluetooth unavailable Use the platform-specific target and check permissions and backend.

Documentation build errors

See Building the Documentation for the pinned DocFX tool and the fix for locked _site/toc.json. Generated output should not be tracked in Git.

Search documentation